Swiftech H20 220 APEX ULTIMA PLUS User Manual Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 17
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
ITEM NO. PART NUMBER DESCRIPTION QTY
.
1 BCKT1 "L" bracket 1
2 BCKT2 "U" bracket 2
3
90272A146-6-32x3-8-philips
3
4 91772A158-6-32X1.75
6-32 x 1 3/4" Philips screw
2
5 90760A007 6-32 Nut w/teeth washer 3
6 FW150X437X092 Rubber Washer 437X150X092 2
7 93286A041-WASHER
zinc plated washer
5
.150"
(3.8MM) HOLE
DRILL ONE
HANGING MOUNT
Panel
1
5
4
7
2
3
6
UPRIGHT MOUNT
Panel
BACK-PANEL MOUNT
Panel
2.00 " (50.8mm) APART
DRILL TWO
0.150" HOLES
6-32 x 3/8” Philips screw
MCRes Micro
Bracketry installation and
examples
Note 1: rubber washer 6
should be inserted between
either side of the reservoir
ear and the U bracket 2.
4
6
7
5
Reservoir ear
2
Note 2: the 6-32 x 1 3/4” screw #4 & nut # 5 assembly is designed to protrude as little as possible in order
to reduce overall clearance necessary for the Micro Res assembly. It is thus necessary to slightly push the nut
in order to engage it on the screw thread.
Preparing the coolant
Your kit comes with a 2 Oz (60ml) bottle of Swiftech’s specially formulated HydrX concentrated coolant. The
product should be mixed with
distilled water only. Simply empty the concentrated coolant into a 33 fl oz (1 liter)
plastic bottle, and complete filling with distilled water. Your coolant is now ready. Note: a 5% mix might still allow
some algae formation over prolonged usage if your system is continuously exposed to daylight (such as a clear
acrylic case for example). Under such circumstances, we would suggest using a 10% mix.
Use of alcohols (Alcohol Allyl, Amyl, Benzyl, Ethyl (Ethanol), Isopropyl, Methyl (Methanol), n-Butyl) or
antifreeze products containing the listed alcohols is prohibited as it will result in deterioration of the
reservoir over-time, and will void your warranty. Resistance to Ethylene and Methylene glycol used in antifreeze
products is excellent.
Minimum Operating Level is situated at the Swiftech Logo (approximately ½” of the reservoir). The reservoir should
not be operated below this level, which could result in degradation of the system cooling.